You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

Element Description

Note: This wiki page is a draft/ work in progress

The Collection Data Type element  is used to identify the collection as a Science Quality Collection or as a non-science-quality collection such as a Near Real Time collection.

Best Practices

 If a collection does not contain this field, it will be assumed to be of science-quality.

SCIENCE_QUALITY: All EOS and non-EOS data and data products that are archived.

NEAR_REAL_TIME: Data from the source that are available for use within a time that is short in comparison to important time scales in the phenomena being studied. This data is not science quality and is not retained by EOSDIS once the SCIENCE_QUALITY product is archived.

OTHER: Any EOS and non-EOS data and data products, that are not SCIENCE_QUALITY and do not fall under NEAR_REAL_TIME holdings.

Examples:

CollectionDataType: Near_Real_Time


Element Specification

Providing the Collection Data Type element is optional (Cardinality: 0..1)

ModelElementTypeConstraintsRequired?Cardinality
UMM-CCollectionDataTypeEnumeration

SCIENCE_QUALITY

NEAR_REAL_TIME

OTHER

No0..1

Metadata Validation and QA/QC

All metadata entering the CMR goes through the below process to ensure metadata quality requirements are met. All records undergo CMR validation before entering the system. The process of QA/QC is slightly different for NASA and non-NASA data providers. Non-NASA providers include interagency and international data providers and are referred to as the International Directory Network (IDN).

Please see the expandable sections below for flowchart details.


  • Manual Review
  • Automated Review


<>

ARC Priority Matrix

Priority CategorizationJustification

This element is categorized as highest priority when:


This element is categorized as medium priority when:


This element is categorized as low priority when:


The element is provided, and follows all applicable criteria specified in the best practices section above.

ARC Automated Rules

  • If no value is provided, return is "np"
  • Otherwise, return is "OK"

Dialect Mappings

DIF 9 (Note: DIF-9 is being phased out and will no longer be supported after 2018)

DIF 10

Providing the Collection Data Type element is optional (Cardinality: 0..1)

SpecificationPathTypeConstraintsRequired in DIF 10?Cardinality
DIF 10Collection_Data_Type



No

0..1


Example Mapping

DIF 10

<Collection_Data_Type>NEAR_REAL_TIME</Collection_Data_Type>

UMM

CollectionDataType: "SCIENCE_QUALITY",

ECHO 10

Providing the Collection Data Type element is optional (Cardinality: 0..1)

SpecificationPathTypeConstraintsRequired in ECHO10?CardinalityNotes
ECHO 10CollectionDataTypeEnumeration

SCIENCE_QUALITY

NEAR_REAL_TIME

OTHER

No0..1



Example Mapping

ECHO 10

N/A     

UMM

Quality: "Users are advised that ASTER SWIR data acquired from late April 2008 to the present exhibit anomalous saturation of values and anomalous striping. This effect is also present for some prior acquisition periods. Please refer to the ASTER SWIR User Advisory Document (https://lpdaac.usgs.gov/sites/default/files/public/aster/docs/ASTER_SWIR_User_Advisory_July%2018_08.pdf) for more details.",

ISO 19115-2 MENDS

Providing the Quality element is optional (Cardinality: 0..1)

SpecificationPathTypeNotes
ISO 19115-2 MENDS/gmi:MI_Metadata/gmd:dataQualityInfo/gmd:DQ_DataQuality/gmd:report/gmd:DQ_QuantitativeAttributeAccuracy/gmd:evaluationMethodDescription/gco:CharacterString

String

Maps to the UMM element "Quality"


Example Mapping

ISO 19115-2 MENDS

<gmi:MI_Metadata>
  <gmd:dataQualityInfo>
    <gmd:DQ_DataQuality>
      <gmd:report>
        <gmd:DQ_QuantitativeAttributeAccuracy>
          <gmd:evaluationMethodDescription>
            <gco:CharacterString>Users are advised that ASTER SWIR data acquired from late April 2008 to the present exhibit anomalous saturation of values and anomalous striping. This effect is also present for some prior acquisition periods. Please refer to the ASTER SWIR User Advisory Document (https://lpdaac.usgs.gov/sites/default/files/public/aster/docs/ASTER_SWIR_User_Advisory_July%2018_08.pdf) for more details.
            </gco:CharacterString>
          </gmd:evaluationMethodDescription>
        </gmd:DQ_QuantitativeAttributeAccuracy>
      </gmd:report>
    </gmd:DQ_DataQuality>
  </gmd:dataQualityInfo>
</gmi:MI_Metadata>

UMM

Quality: "Users are advised that ASTER SWIR data acquired from late April 2008 to the present exhibit anomalous saturation of values and anomalous striping. This effect is also present for some prior acquisition periods. Please refer to the ASTER SWIR User Advisory Document (https://lpdaac.usgs.gov/sites/default/files/public/aster/docs/ASTER_SWIR_User_Advisory_July%2018_08.pdf) for more details."

ISO 19115-2 SMAP

Providing the Quality element is optional. (Cardinality: 0..1)

SpecificationPathTypeNotes
ISO 19115-2 SMAP

/gmd:DS_Series/gmd:seriesMetadata/gmi:MI_Metadata/gmd:dataQualityInfo/gmd:DQ_DataQuality/gmd:report/gmd:DQ_QuantitativeAttributeAccuracy/gmd:evaluationMethodDescription/gco:CharacterString

String

Maps to the UMM element "Quality"


Example Mapping

ISO 19115-2 SMAP

<gmd:DS_Series>
<gmd:seriesMetadata>
<gmi:MI_Metadata>
  <gmd:dataQualityInfo>
    <gmd:DQ_DataQuality>
      <gmd:report>
        <gmd:DQ_QuantitativeAttributeAccuracy>
          <gmd:evaluationMethodDescription>
            <gco:CharacterString>Users are advised that ASTER SWIR data acquired from late April 2008 to the present exhibit anomalous saturation of values and anomalous striping. This effect is also present for some prior acquisition periods. Please refer to the ASTER SWIR User Advisory Document (https://lpdaac.usgs.gov/sites/default/files/public/aster/docs/ASTER_SWIR_User_Advisory_July%2018_08.pdf) for more details.
            </gco:CharacterString>
          </gmd:evaluationMethodDescription>
        </gmd:DQ_QuantitativeAttributeAccuracy>
      </gmd:report>
    </gmd:DQ_DataQuality>
  </gmd:dataQualityInfo>
</gmi:MI_Metadata>
</gmd:DS_Series>
</gmd:seriesMetadata>

UMM

Quality: "Users are advised that ASTER SWIR data acquired from late April 2008 to the present exhibit anomalous saturation of values and anomalous striping. This effect is also present for some prior acquisition periods. Please refer to the ASTER SWIR User Advisory Document (https://lpdaac.usgs.gov/sites/default/files/public/aster/docs/ASTER_SWIR_User_Advisory_July%2018_08.pdf) for more details."

UMM Migration

UMM Version 1.9.0Translation DirectionUMM Version 1.10.0



Future Mappings

ISO 19115-1

Providing the Quality element is optional (Cardinality: 0..1)

SpecificationPathTypeNotes
ISO 19115-1

/mdb:MD_Metadata/mdb:dataQualityInfo/mdq:DQ_DataQuality/mdq:report/mdq:DQ_DomainConsistency/mdq:result/mdq:DQ_DescriptiveResult/mdq:statement/gco:CharacterString

String

Maps to the UMM element "Quality"


Example Mapping

ISO 19115-1

<mdb:MD_Metadata>
  <mdb:dataQualityInfo>
    <mdq:DQ_DataQuality>
      <mdq:report>
        <mdq:DQ_DomainConsistency>
          <mdq:result>
            <mdq:DQ_DescriptiveResult>
              <mdq:statement>
                <gco:CharacterString>Users are advised that ASTER SWIR data acquired from late April 2008 to the present exhibit anomalous saturation of values and anomalous striping. This effect is also present for some prior acquisition periods. Please refer to the ASTER SWIR User Advisory Document (https://lpdaac.usgs.gov/sites/default/files/public/aster/docs/ASTER_SWIR_User_Advisory_July%2018_08.pdf) for more details.
                </gco:CharacterString>
              </mdq:statement>
            </mdq:DQ_DescriptiveResult>
          </mdq:result>
        </mdq:DQ_DomainConsistency>
      </mdq:report>
    </mdq:DQ_DataQuality>
  </mdb:dataQualityInfo>
</mdb:MD_Metadata>

UMM

Quality: "Users are advised that ASTER SWIR data acquired from late April 2008 to the present exhibit anomalous saturation of values and anomalous striping. This effect is also present for some prior acquisition periods. Please refer to the ASTER SWIR User Advisory Document (https://lpdaac.usgs.gov/sites/default/files/public/aster/docs/ASTER_SWIR_User_Advisory_July%2018_08.pdf) for more details."

Both ISO conventions (19115-1 & 2) have sub-fielded text that more precisely describe the quality assessment of a resource.  Please refer to ISO 19157 (Geographic information – Data quality) for more information about data quality in ISO.

History

UMM Versioning

VersionDateWhat Changed
1.10.05/2/2018

No changes were made for Quality during the transition from version 1.9.0 to 1.10.0

1.9.0

ARC Documentation

VersionDateWhat ChangedAuthor
1.011/2/18Recommendations/priority matrix transferred from internal ARC documentation to wiki spaceJeanne' le Roux
  • No labels